Multifunction control unit, TeSys U, 4.5-18A, 1P/3P motors, protection & diagnostic, class 5-30, coil 24V DC

Multifunction control unit, TeSys U, 4.5-18A, 1P/3P motors, protection & diagnostic, class 5-30, coil 24V DC

SQDLUCM18BL LUCM18BL 785901320555
424.36 / EACH
  • Certifications: ASEFA, ATEX, CCC, CE, CSA, EAC, Marine, UL
  • Country of Origin: France
  • Depth: 2.36 in, 60 mm
  • Height: 2.60 in, 66 mm
  • Standard: CSA C22.2 No 60947-4-1, With Phase Barrier, EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, With Phase Barrier
  • Voltage: 690 V
  • Warranty Length: 18 mth
  • Weight: 0.175 kg, 0.39 lb
  • Width: 1.77 in, 45 mm
TeSys U multifunction control unit to be inserted in advanced power bases LUB320, LUB380 to form a TeSys U starter controller, for 1-phase motor applications up to 4kW@400V and 3-phase up to 7.5kW@400V. It provides full protection to motors with a rated current Ir 4.5-18A (Ir adjustable), overload class selectable 5-30, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). Equipped with a LCD display and a 4-button keyboard for the setting of protection and alarm parameters, and display of electrical values and events. RS485 Modbus communication RJ45 port available for remote control and integration with SoMove/MachineExpert. To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base), it must be supplied with an external 24V DC power supply. Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
  • Product Description
  • Specifications
TeSys U multifunction control unit to be inserted in advanced power bases LUB320, LUB380 to form a TeSys U starter controller, for 1-phase motor applications up to 4kW@400V and 3-phase up to 7.5kW@400V. It provides full protection to motors with a rated current Ir 4.5-18A (Ir adjustable), overload class selectable 5-30, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). Equipped with a LCD display and a 4-button keyboard for the setting of protection and alarm parameters, and display of electrical values and events. RS485 Modbus communication RJ45 port available for remote control and integration with SoMove/MachineExpert. To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base), it must be supplied with an external 24V DC power supply. Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
  • Environment
    • IP Degree Of Protection : IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
    • Ambient Air Temp For Storage : -40…185 °F (-40…85 °C)
    • Immunity To Microbreaks : 3 ms
    • Immunity To Voltage Dips : 70 % / 500 ms IEC 61000-4-11
    • Vibration Resistance : 2 gn 5…300 Hz power poles open IEC 60068-2-6 || 4 gn 5…300 Hz power poles closed IEC 60068-2-6
    • Shock Resistance : 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
    • Ambient Air Temp For Op : -13…140 °F (-25…60 °C)
    • Resistance To Fast Transients : 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
    • Imm To Radioelectric Fields : 10 V IEC 61000-4-6
    • Resist Electrostatic Dischrg : 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
    • Protective Treatment : TH conforming to IEC 60068
    • Resistance To Radiated Fields : 9.14 V/m (10 V/m) 3 IEC 61000-4-3
    • Non-Dissipating Shock Wave : 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
    • Operating Altitude : 6561.68 ft (2000 m)
    • Fire Resistance : 1760 °F (960 °C) parts supporting live components IEC 60695-2-12 || 1202 °F (650 °C) IEC 60695-2-12
  • Main
    • Network Frequency : 40...60 Hz
    • Load Type : 3-phase motor self-cooled factory setting || 3-phase motor self-cooled, force cooled settable || Single-phase motor self-cooled, force cooled settable
    • Product Name : TeSys U
    • Range Of Product : TeSys U
    • Device Short Name : LUCM
    • Utilisation Category : AC-41 || AC-43 || AC-44
    • Range : TeSys
    • Motor Power kW : 7.5 kW 400...440 V AC 50/60 Hz 3 phase || 9 kW 500 V AC 50/60 Hz 3 phase || 15 kW 690 V AC 50/60 Hz 3 phase || 4 kW 400...440 V AC 50/60 Hz 1 phase
    • [Uc] Control Circuit Voltage : 24 V DC
    • Product Compatibility : Power base LUB32 || Power base LUB38 || Power base LUB320 || Power base LUB380 || Reversing contactor breaker LU2B32FU || Reversing contactor breaker LU2B38FU
    • Main Function Available : Manual or automatic reset || Protection function alarm || Protection against phase failure and phase imbalance || Protection against overload and short-circuit || Monitoring function, indication of main motor parameters || Log function || Earth fault protection || Differentiation of thermal overload and magnetic fault || Overload, no-load running
    • Rated Motor Current Adjustment Range : 4.5…18 A
    • Product Specific Application : Most sophisticated control and protection requirements, with display
    • Ue Rated Operational Voltage : 690 V AC
    • Tripping Threshold : 14.2 x Ir +/- 20 %
    • Device Application : Motor control || Motor protection
    • Product Or Component Type : Multifunction control unit
    • Thermal Overload Class : Class 5…30 50…60 Hz -13…131 °F (-25…55 °C) IEC 60947-6-2 || Class 5…30 50…60 Hz -13…131 °F (-25…55 °C) UL 508
  • Ordering And Shipping Details
    • Category : 22398 - TESYS U - MULTI-FCTN CTRL MOD(LUCM)
    • GTIN : 00785901320555
    • Returnability : No
    • Country Of Origin : FR
    • Nbr. Of Units In Pkg. : 1
    • Discount Schedule : I11
  • Contractual Warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Mercury Free : Yes
    • Halogen Content Performance : Halogen free plastic parts product
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Green Premium Status : Green Premium product
    • EU RoHs Directive : Compliant
    • Pvc Free : Yes
  • Complementary
    • Height : 2.60 in (66 mm)
    • Typical Current Consumption : 220 mA 24 V DC I maximum while closing with LUB32 || 220 mA 24 V DC I maximum while closing with LUB38 || 80 mA 24 V DC I rms sealed with LUB32 || 80 mA 24 V DC I rms sealed with LUB38
    • Heat Dissipation : 1.8 W control circuit with LUB32 || 1.8 W control circuit with LUB38 || 0.8 W external auxiliary circuit
    • Product Weight : 0.39 lb(US) (0.175 kg)
    • Standards : EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
    • Product Certifications : CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
    • Return Time : <= 200 ms
    • Information Displayed : Average current factory setting) || Average current settable) || Cause of last 5 faults settable) || Current in phase settable) || Earth leakage current settable) || Phase imbalance settable) || Thermal state of motor settable)
    • Compatibility Code : LUCM
    • Fixing Mode : Plug-in front face)
    • Reset : Automatic reset setting range || Manual factory setting || Manual setting range || Remote reset setting range
    • Depth : 2.36 in (60 mm)
    • Operating Time : 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 65 ms closing with LUB32 control circuit || 65 ms closing with LUB38 control circuit
    • Width : 1.77 in (45 mm)
    • Ctrl Circuit Voltage Limits : 20...28 V DC 24 V in operation || 14.5 V DC 24 V drop-out
    • Uimp Rated Imp Wstd Voltage : 6 kV IEC 60947-6-2
    • Time Before Reset : 1…1000 s manual or automatic reset settable || 120 s manual factory setting
    • Messages Display Capacity : 2 lines of 12 characters LCD - English +/- 5 % 1 % of Ir || 2 lines of 12 characters LCD - French +/- 5 % 1 % of Ir || 2 lines of 12 characters LCD - German +/- 5 % 1 % of Ir || 2 lines of 12 characters LCD - Italian +/- 5 % 1 % of Ir || 2 lines of 12 characters LCD - Spanish +/- 5 % 1 % of Ir
    • Physical Interface : RS485 multidrop RJ45 front panel Modbus RTU 19200 bit/s
    • Ui Rated Insulation Voltage : 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
    • User Language : English factory setting || English, French, German, Italian, Spanish settable
    • Safe Separation Of Circuit : 400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1