SQUARE D

Multifunction control unit, TeSys U, 1.25-5A, 1P/3P motors, protection & diagnostic, class 5-30, coil 24V DC

MULTIFUNCTION CNTRL.UNIT 1.25-

SQDLUCM05BL LUCM05BL 785901276388
424.36 / EACH
  • Certifications: ASEFA, ATEX, CCC, CE, CSA, EAC, Marine, UL
  • Depth: 60 mm
  • Height: 66 mm
  • Net Weight: 0.175 kg
  • Standard: CSA C22.2 No 60947-4-1, With Phase Barrier, EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, With Phase Barrier
  • Storage Temperature: -40-85 °C
  • Width: 45 mm
TeSys U multifunction control unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 1-phase motor applications up to 0.55kW@400V and 3-phase up to 1.5kW@400V. It provides full protection to motors with a rated current Ir 1.25-5A (Ir adjustable), overload class selectable 5-30, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). Equipped with a LCD display and a 4-button keyboard for the setting of protection and alarm parameters, and display of electrical values and events. RS485 Modbus communication RJ45 port available for remote control and integration with SoMove/MachineExpert. To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base), it must be supplied with an external 24V DC power supply. Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
  • Product Description
  • Specifications
TeSys U multifunction control unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 1-phase motor applications up to 0.55kW@400V and 3-phase up to 1.5kW@400V. It provides full protection to motors with a rated current Ir 1.25-5A (Ir adjustable), overload class selectable 5-30, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). Equipped with a LCD display and a 4-button keyboard for the setting of protection and alarm parameters, and display of electrical values and events. RS485 Modbus communication RJ45 port available for remote control and integration with SoMove/MachineExpert. To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base), it must be supplied with an external 24V DC power supply. Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
  • Tripping Threshold : 14.2 x Ir +/- 20 %
  • Fire Resistance : 960 °C parts supporting live components IEC 60695-2-12 || 650 °C IEC 60695-2-12
  • Operating Time : 35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 75 ms closing with LUB12 control circuit || 65 ms closing with LUB32 control circuit || 65 ms closing with LUB38 control circuit
  • Maximum Depth : 60 mm
  • Resistance To Electrostatic Discharge : 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
  • Safe Separation Of Circuit : 400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
  • User Language : English factory setting || English, French, German, Italian, Spanish settable
  • Motor Power Kw : 1.5 kW 400...440 V AC 50/60 Hz 3 phase || 2.2 kW 500 V AC 50/60 Hz 3 phase || 3 kW 690 V AC 50/60 Hz 3 phase || 0.55 kW 400...440 V AC 50/60 Hz 1 phase
  • Utilisation Category : AC-41 || AC-44 || AC-43
  • Immunity To Microbreaks : 3 ms
  • Typical Current Consumption : 150 mA 24 V DC I maximum while closing with LUB12 || 200 mA 24 V DC I maximum while closing with LUB32 || 200 mA 24 V DC I maximum while closing with LUB38 || 70 mA 24 V DC I rms sealed with LUB12 || 75 mA 24 V DC I rms sealed with LUB32 || 75 mA 24 V DC I rms sealed with LUB38
  • Device Application : motor control || motor protection
  • Return Time : <= 200 ms
  • Time Before Reset : 1-1000 s manual or automatic reset settable || 120-120 s manual factory setting
  • Maximum Height : 66 mm
  • Range : TeSys
  • Immunity To Radioelectric Fields : 10 V IEC 61000-4-6
  • Reset : automatic reset setting range || manual factory setting || manual setting range || remote reset setting range
  • Ambient Air Temperature For Storage : -40-85 °C
  • Vibration Resistance : 2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6
  • Standards : EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
  • Fixing Mode : plug-in front face)
  • Function Available : protection function alarm || earth fault protection || protection against phase failure and phase imbalance || manual or automatic reset || log function || protection against overload and short-circuit || differentiation of thermal overload and magnetic fault || overload, no-load running || monitoring function, indication of main motor parameters
  • Information Displayed : average current factory setting) || average current settable) || cause of last 5 faults settable) || current in phase settable) || earth leakage current settable) || phase imbalance settable) || thermal state of motor settable)
  • Ip Degree Of Protection : IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
  • Ambient Air Temperature For Operation : -25-60 °C
  • Control Circuit Voltage Limits : 20...28 V DC 24 V in operation || 14.5 V DC 24 V drop-out
  • Maximum Width : 45 mm
  • [Ue] Rated Operational Voltage : 690 V AC
  • [Ui] Rated Insulation Voltage : 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
  • Physical Interface : RS485 multidrop RJ45 front panel Modbus RTU 19200 bit/s
  • Resistance To Fast Transients : 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
  • Compatibility Code : LUCM
  • Product Or Component Type : multifunction control unit
  • Protective Treatment : TH IEC 60068
  • Heat Dissipation : 1.7-1.7 W control circuit with LUB12 || 1.8-1.8 W control circuit with LUB32 || 1.8-1.8 W control circuit with LUB38 || 0.8-0.8 W external auxiliary circuit
  • Thermal Protection Adjustment Range : 1.25-5 A
  • Product Specific Application : most sophisticated control and protection requirements, with display
  • Load Type : 3-phase motor self-cooled factory setting || 3-phase motor self-cooled, force cooled settable || single-phase motor self-cooled, force cooled settable
  • Messages Display Capacity : 2 lines of 12 characters LCD - English +/- 5 % 1 % of Ir || 2 lines of 12 characters LCD - French +/- 5 % 1 % of Ir || 2 lines of 12 characters LCD - German +/- 5 % 1 % of Ir || 2 lines of 12 characters LCD - Italian +/- 5 % 1 % of Ir || 2 lines of 12 characters LCD - Spanish +/- 5 % 1 % of Ir
  • Net Weight : 0.175 kg
  • Range Of Product : TeSys U
  • Immunity To Voltage Dips : 70 % / 500 ms IEC 61000-4-11
  • Network Frequency : 40...60 Hz
  • Product Name : TeSys U
  • [Uc] Control Circuit Voltage : 24 V DC
  • Device Short Name : LUCM
  • Resistance To Radiated Fields : 10 V/m 3 IEC 61000-4-3
  • Shock Resistance : 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
  • Thermal Overload Class : class 5…30 50-60 Hz -25-55 °C IEC 60947-6-2 || class 5…30 50-60 Hz -25-55 °C UL 508
  • Operating Altitude : 6561.68 ft (2000 m)
  • Product Certifications : CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
  • Product Compatibility : power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12BL || reversing contactor breaker LU2B32BL || reversing contactor breaker LU2B38BL
  • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947-6-2