The Preventa XCS range is an offer of safety switches. They are designed for controlling the safe opening and interlocking of guards and covers. This coded magnetic switch is dedicated to detection without contact. 3 approach directions. It features a rectangular plastic boby, and 10m long pre-cabled electrical connection . 3-pole 2 NC + 1 NO (1NC staggered).
The Preventa XCS range is an offer of safety switches. They are designed for controlling the safe opening and interlocking of guards and covers. This coded magnetic switch is dedicated to detection without contact. 3 approach directions. It features a rectangular plastic boby, and 10m long pre-cabled electrical connection . 3-pole 2 NC + 1 NO (1NC staggered).
Specifications
Range Of Product : Telemecanique Safety switches XCS
[Ue] Rated Operational Voltage : 24 V DC
Cable Length : 10 m
Product Or Component Type : coded magnetic switch
Component Name : XCSDMP
Design : rectangular, standard
Material : plastic
Size : 88 x 25 x 13 mm
Contacts Type And Composition : 2 NC + 1 NO
Contact Operation : 1 NC staggered
Electrical Connection : pre-cabled
Cable Composition : 6 x 0.25 mm²
Approach Directions : 3 directions
[Ui] Rated Insulation Voltage : 100 V DC
Number Of Poles : 3
Contractual warranty
Warranty : 18 months
Complementary
Maximum [Ie] Rated Operational Current : 100 mA
Height : 88 mm
Switching Frequency : 150 Hz
Short-Circuit Protection : 500 mA external cartridge fuse gG (gl)
Switching Capacity In Ma : 0.1...100 mA
[Sar] Assured Tripping Distance : 20 mm
Contacts Material : rhodium
Insulation Resistance : 1000 MOhm
Resistance Across Terminals : 10 Ohm
Net Weight : 0.18 kg
[Uimp] Rated Impulse Withstand Voltage : 2.5 kV EN/IEC 60947-5-1
Maximum Switching Voltage : 100 V DC
[Sa] Assured Operating Distance : 8 mm
Cable Material : PVC
Breaking Capacity : 10 VA
Safety Reliability Data : B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure Material : thermoplastic PBT
Width : 25 mm
Depth : 13 mm
Electrical Durability : 1200000 cycles
Safety Level : can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Offer Sustainability
Rohs Exemption Information : Yes
Mercury Free : Yes
Toxic Heavy Metal Free : Yes
Reach Regulation : Free of Substances of Very High Concern above the threshold
California Proposition 65 : WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc : Yes
Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
Environment
Product Certifications : CSA || UL
Ambient Air Temperature For Operation : -25-85 °C
Standards : EN/ISO 12100 || UL 508 || EN/IEC 60947-5-1 || EN/IEC 60204-1 || CSA C22.2 No 14 || ISO 14119
Shock Resistance : 30 gn 11 ms IEC 60068-2-27
Vibration Resistance : 10 gn 10-150 Hz)IEC 60068-2-6
Ip Degree Of Protection : IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529
Ambient Air Temperature For Storage : -40-85 °C
Electrical Shock Protection Class : class II EN/IEC 61140