Multi9 - C60H - MCB - 3P - 6 A - D Curve - 415 V - 15 kA

Multi9 - C60H - MCB - 3P - 6 A - D Curve - 415 V - 15 kA

SQDM9F15306 M9F15306 360648057772
0.00 / EA
  • Amperage: 6 A
  • Certifications: CCC, EAC
  • Country of Origin: France
  • Depth: 2.83 in, 72 mm
  • Height: 3.19 in, 81 mm
  • Mounting Type: Clip-On
  • Standard: EN/IEC 60947-2
  • Strip Length: 0.55 in, 14 mm
  • Voltage: 125 V, 240 V, 415 V, 440 V
  • Weight: 0.36 kg, 0.79 lb
  • Width: 2.13 in, 54 mm
This Multi9 C60H is a low voltage miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles, 6A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 15kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 6 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is light grey (RAL7035). The dimensions are (W) 54mm x (H) 81mm x (D) 72mm. The weight is 0.36kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60H is a low voltage miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles, 6A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 15kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 6 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is light grey (RAL7035). The dimensions are (W) 54mm x (H) 81mm x (D) 72mm. The weight is 0.36kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Complementary
    • Depth : 2.83 in (72 mm)
    • Product Weight : 0.79 lb(US) (0.36 kg)
    • Magnetic Tripping Limit : 12 x In +/- 20 % AC || 17 x In +/- 20 % DC
    • Height : 3.19 in (81 mm)
    • Electrical Durability : 10000 cycles
    • 9 mm Pitches : 6
    • Control Type : Toggle
    • Ics Rated Service Breaking Cap : 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz || 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz || 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz || 40 kA 100 % EN/IEC 60947-2 - <= 125 V DC
    • Uimp Rated Imp Wstd Voltage : 6 kVEN/IEC 60947-2
    • Tightening Torque : 17.70 lbf.in (2 N.m) top or bottom
    • Local Signalling : ON/OFF indication
    • Mechanical Durability : 20000 cycles
    • Ue Rated Operational Voltage : 240 V AC 50/60 Hz between phases || 415 V AC 50/60 Hz between phases || 440 V AC 50/60 Hz between phases || <= 125 V DC
    • Wire Stripping Length : 0.55 in (14 mm) top or bottom
    • Colour : Gray
    • Mounting Support : DIN rail
    • Contact Position Indicator : Yes
    • Network Frequency : 50/60 Hz
    • Ui Rated Insulation Voltage : 500 V AC 50/60 Hz EN/IEC 60947-2
    • Provision For Padlocking : Padlockable
    • Connections - Terminals : Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) - rigid || Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) - flexible || Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) - flexible with ferrule
    • Mounting Mode : Clip-on
    • Earth-Leakage Protection : Separate block
    • Width : 2.13 in (54 mm)
  • Ordering And Shipping Details
    • Category : 00908 - C60N SUPPLEMENTARY PROTECTORS
    • Nbr. Of Units In Pkg. : 1
    • Returnability : No
    • Country Of Origin : FR
    • GTIN : 03606480577727
    • Discount Schedule : DE2
  • Environment
    • Heat Dissipation : 8.1 W 415 V - 6 A
    • IP Degree Of Protection : IP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
    • Tropicalisation : 2 conforming to IEC 60068-1
    • Ambient Air Temp For Storage : -40…176 °F (-40…80 °C)
    • Relative Humidity : 95 % 131 °F (55 °C)
    • Ambient Air Temp For Op : -22…158 °F (-30…70 °C)
    • Pollution Degree : 3 EN/IEC 60947-2
    • Overvoltage Category : IV
  • Main
    • Product Or Component Type : Miniature circuit-breaker
    • Standards : EN/IEC 60947-2
    • Suitability For ISOlation : Yes conforming to EN/IEC 60947-2
    • Curve Code : D
    • Product Name : Multi 9 C60
    • Utilisation Category : Category A EN/IEC 60947-2
    • Network Type : AC || DC
    • Poles Description : 3P
    • Device Short Name : C60H
    • In Rated Current : 6 A 122 °F (50 °C) EN/IEC 60947-2
    • Range : Multi 9
    • Number Of Protected Poles : 3
    • Breaking Capacity : 40 kA Icu <= 125 V DC EN/IEC 60947-2 || 30 kA Icu 240 V AC 50/60 Hz between phases EN/IEC 60947-2 || 15 kA Icu 415 V AC 50/60 Hz between phases EN/IEC 60947-2 || 10 kA Icu 440 V AC 50/60 Hz between phases EN/IEC 60947-2
    • Product Certifications : EAC || CCC
    • Device Application : Distribution
    • Trip Unit Technology : Thermal-magnetic
  • Offer Sustainability
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Halogen Content Performance : Halogen free plastic parts & cables product
    • EU RoHs Directive : Compliant
    • Green Premium Status : Green Premium product
    • Mercury Free : Yes