Multi9 - C60H-DC - MCB - 2P - 1 A - D Curve - 500 V DC - 10 kA

Multi9 - C60H-DC - MCB - 2P - 1 A - D Curve - 500 V DC - 10 kA

SQDM9U31201 M9U31201 785901777908
220.64 / EA
  • Amperage: 1 A
  • Certifications: CCC, IEC, UR
  • Country of Origin: China
  • Depth: 2.87 in, 73 mm
  • Height: 3.19 in, 81 mm
  • Mounting Type: Clip-On
  • Standard: EN/IEC 60947-2, GB 14048.2, UL 1077
  • Strip Length: 0.55 in, 14 mm
  • Voltage: 220 V, 440 V, 500 V
  • Weight: 0.256 kg, 0.56 lb
  • Width: 1.42 in, 36 mm
This Multi9 C60H-DC is a low voltage miniature circuit breaker (MCB) dedicated to direct current. It is a 2P circuit breaker with 2 protected poles, 1A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 20kA at 220VDC conforming to EN/IEC 60947-2 standard and 20kA at 220VDC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 220VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 73mm. The weight is 0.256kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.
  • Product Description
  • Specifications
This Multi9 C60H-DC is a low voltage miniature circuit breaker (MCB) dedicated to direct current. It is a 2P circuit breaker with 2 protected poles, 1A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 20kA at 220VDC conforming to EN/IEC 60947-2 standard and 20kA at 220VDC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 220VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 73mm. The weight is 0.256kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.
  • Main
    • Network Type : DC
    • Suitability For ISOlation : Yes EN/IEC 60947-2
    • Number Of Protected Poles : 2
    • Product Name : Multi 9 C60H-DC
    • Device Short Name : C60H-DC
    • Product Certifications : IEC || CCC || UR
    • Product Or Component Type : Miniature circuit-breaker
    • Range : Multi 9
    • Utilisation Category : Category A EN/IEC 60947-2
    • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 1077
    • Breaking Capacity : 20 kA Icu 220 V DC EN/IEC 60947-2 || 10 kA Icu 440 V DC EN/IEC 60947-2 || 6 kA Icu 500 V DC EN/IEC 60947-2 || 5 kA AIR 12...500 V DC UL 1077 || 20 kA Icu 220 V DC GB 14048.2 || 10 kA Icu 440 V DC GB 14048.2 || 6 kA Icu 500 V DC GB 14048.2
    • Device Application : Distribution
    • Poles Description : 2P
    • In Rated Current : 1 A 77 °F (25 °C) EN/IEC 60947-2
    • Curve Code : D
    • Trip Unit Technology : Thermal-magnetic
  • Environment
    • Relative Humidity : 95 % 131 °F (55 °C)
    • Ambient Air Temp For Op : -13…158 °F (-25…70 °C)
    • Ambient Air Temp For Storage : -40…185 °F (-40…85 °C)
    • Pollution Degree : 3 EN/IEC 60947-2
    • IP Degree Of Protection : IP20 conforming to IEC 60529 || IP40 modular enclosure)IEC 60529
    • Tropicalisation : 2 IEC 60068-2 || 2 GB 14048.2
    • Heat Dissipation : 4.6 W 440 V - 1 A
  • Offer Sustainability
    • REACh Free Of SVHC : Yes
    • Toxic Heavy Metal Free : Yes
    • EU RoHs Directive : Compliant
    • Mercury Free : Yes
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • Ordering And Shipping Details
    • Country Of Origin : CN
    • GTIN : 00785901777908
    • Returnability : No
    • Nbr. Of Units In Pkg. : 1
    • Category : 00948 - M9 GEN 2 CB UL1077 / IEC
    • Discount Schedule : DE2
  • Complementary
    • Width : 1.42 in (36 mm)
    • Ui Rated Insulation Voltage : 500 V DC EN/IEC 60947-2
    • Depth : 2.87 in (73 mm)
    • Mounting Support : DIN rail
    • Ics Rated Service Breaking Cap : 7.5 kA 75 % EN/IEC 60947-2 - 440 V DC || 4.5 kA 75 % EN/IEC 60947-2 - 500 V DC || 15 kA 75 % EN/IEC 60947-2 - 220 V DC || 7.5 kA 75 % GB 14048.2 - 440 V DC || 4.5 kA 75 % GB 14048.2 - 500 V DC || 15 kA 75 % GB 14048.2 - 220 V DC
    • Contact Position Indicator : Yes
    • Colour : Gray
    • Earth-Leakage Protection : Without
    • Control Type : Toggle
    • Product Weight : 0.56 lb(US) (0.256 kg)
    • Ue Rated Operational Voltage : 220 V DC || 440 V DC || 500 V DC
    • Mounting Mode : Clip-on
    • Height : 3.19 in (81 mm)
    • Mechanical Durability : 20000 cycles
    • Local Signalling : ON/OFF indication
    • Wire Stripping Length : 0.55 in (14 mm) top or bottom
    • Connections - Terminals : Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 4) - rigid stranded || Tunnel type terminal top or bottom) 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 6) - flexible || Tunnel type terminal top or bottom) 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 6) - flexible with ferrule || Tunnel type terminal top or bottom) - 2 0.00…0.02 in² (1…10 mm²) AWG 18...AWG 8) - rigid stranded || Tunnel type terminal top or bottom) - 2 0.00…0.02 in² (1…10 mm²) AWG 18...AWG 8) - flexible || Tunnel type terminal top or bottom) - 2 0.00…0.02 in² (1…10 mm²) AWG 18...AWG 8) - flexible with ferrule || Tunnel type terminal top or bottom) - 3 0.00 in² (1 mm²) AWG 18) - flexible stranded
    • Electrical Durability : 3000 cycles 250 V DC L/R = 2 ms || 6000 cycles 250 V DC
    • Magnetic Tripping Limit : 10...14 x In DC
    • Provision For Padlocking : Padlockable
    • Uimp Rated Imp Wstd Voltage : 6 kVEN/IEC 60947-2
    • 9 mm Pitches : 4
    • Tightening Torque : 22.13 lbf.in (2.5 N.m) top or bottom