Schneider Electric at Mayer

Multi9 - C60H-DC - MCB - 1P - 32 A - D Curve - 250 V DC - 10 kA

Multi9 C60H-DC 32A K 250V-DC M

SQDM9U31132 M9U31132 785901777700
102.44 / EA
  • Amperage: 32 A
  • Certifications: CCC, IEC, UR
  • Country of Origin: China
  • Depth: 2.87 in, 73 mm
  • Height: 3.19 in, 81 mm
  • Mounting Type: Clip-On
  • Standard: EN/IEC 60947-2, GB 14048.2, UL 1077
  • Strip Length: 0.55 in, 14 mm
  • Voltage: 110 V, 220 V, 250 V
  • Weight: 0.128 kg, 0.28 lb
  • Width: 0.71 in, 18 mm
This Multi9 C60H-DC is a low voltage miniature circuit breaker (MCB) dedicated to direct current. It is a 1P circuit breaker with 1 protected pole, 32A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 10kA at 220VDC conforming to EN/IEC 60947-2 standard and 10kA at 220VDC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 250VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 81mm x (D) 73mm. The weight is 0.128kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.
  • Product Description
  • Specifications
This Multi9 C60H-DC is a low voltage miniature circuit breaker (MCB) dedicated to direct current. It is a 1P circuit breaker with 1 protected pole, 32A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 10kA at 220VDC conforming to EN/IEC 60947-2 standard and 10kA at 220VDC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 250VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 81mm x (D) 73mm. The weight is 0.128kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.
  • Complementary
    • Product Weight : 0.28 lb(US) (0.128 kg)
    • Colour : Gray
    • Connections - Terminals : Tunnel type terminal top or bottom) 0.00…0.05 in² (1…35 mm²) AWG 18...AWG 2) - rigid stranded || Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 4) - flexible || Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 4) - flexible with ferrule || Tunnel type terminal top or bottom) - 2 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 6) - rigid stranded || Tunnel type terminal top or bottom) - 2 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 6) - flexible || Tunnel type terminal top or bottom) - 2 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 6) - flexible with ferrule || Tunnel type terminal top or bottom) - 3 0.01 in² (4 mm²) AWG 6) - flexible stranded
    • Contact Position Indicator : Yes
    • Wire Stripping Length : 0.55 in (14 mm) top or bottom
    • Ue Rated Operational Voltage : 250 V DC || 110 V DC || 220 V DC
    • Mechanical Durability : 20000 cycles
    • Electrical Durability : 3000 cycles 250 V DC L/R = 2 ms || 6000 cycles 250 V DC
    • Earth-Leakage Protection : Without
    • Control Type : Toggle
    • Width : 0.71 in (18 mm)
    • Mounting Support : DIN rail
    • Uimp Rated Imp Wstd Voltage : 6 kVEN/IEC 60947-2
    • 9 mm Pitches : 2
    • Depth : 2.87 in (73 mm)
    • Height : 3.19 in (81 mm)
    • Provision For Padlocking : Padlockable
    • Local Signalling : ON/OFF indication
    • Mounting Mode : Clip-on
    • Ics Rated Service Breaking Cap : 7.5 kA 75 % EN/IEC 60947-2 - 220 V DC || 4.5 kA 75 % EN/IEC 60947-2 - 250 V DC || 15 kA 75 % EN/IEC 60947-2 - 110 V DC || 7.5 kA 75 % GB 14048.2 - 220 V DC || 4.5 kA 75 % GB 14048.2 - 250 V DC || 15 kA 75 % GB 14048.2 - 110 V DC
    • Magnetic Tripping Limit : 10...14 x In DC
    • Ui Rated Insulation Voltage : 500 V DC EN/IEC 60947-2
    • Tightening Torque : 30.98 lbf.in (3.5 N.m) top or bottom
  • Offer Sustainability
    • EU RoHs Directive : Compliant
    • Mercury Free : Yes
    • Toxic Heavy Metal Free : Yes
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • REACh Free Of SVHC : Yes
  • Main
    • In Rated Current : 32 A 77 °F (25 °C) EN/IEC 60947-2
    • Number Of Protected Poles : 1
    • Poles Description : 1P
    • Product Certifications : IEC || CCC || UR
    • Suitability For ISOlation : Yes EN/IEC 60947-2
    • Device Application : Distribution
    • Network Type : DC
    • Product Or Component Type : Miniature circuit-breaker
    • Product Name : Multi 9 C60H-DC
    • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 1077
    • Curve Code : D
    • Device Short Name : C60H-DC
    • Utilisation Category : Category A EN/IEC 60947-2
    • Breaking Capacity : 10 kA Icu 220 V DC EN/IEC 60947-2 || 6 kA Icu 250 V DC EN/IEC 60947-2 || 20 kA Icu 110 V DC EN/IEC 60947-2 || 5 kA AIR 12...250 V DC UL 1077 || 10 kA Icu 220 V DC GB 14048.2 || 6 kA Icu 250 V DC GB 14048.2 || 20 kA Icu 110 V DC GB 14048.2
    • Range : Multi 9
    • Trip Unit Technology : Thermal-magnetic
  • Environment
    • Pollution Degree : 3 EN/IEC 60947-2
    • Ambient Air Temp For Op : -13…158 °F (-25…70 °C)
    • Ambient Air Temp For Storage : -40…185 °F (-40…85 °C)
    • Tropicalisation : 2 IEC 60068-2 || 2 GB 14048.2
    • Heat Dissipation : 3.5 W 220 V - 32 A
    • Relative Humidity : 95 % 131 °F (55 °C)
    • IP Degree Of Protection : IP20 conforming to IEC 60529 || IP40 modular enclosure)IEC 60529
  • Ordering And Shipping Details
    • Country Of Origin : CN
    • GTIN : 00785901777700
    • Returnability : No
    • Category : 00948 - M9 GEN 2 CB UL1077 / IEC
    • Discount Schedule : DE2
    • Nbr. Of Units In Pkg. : 1