Multi 9 - C60BP - MCB - 2P - 45 A - D Curve - 240 V - 10 kA - UL 489

Multi 9 - C60BP - MCB - 2P - 45 A - D Curve - 240 V - 10 kA - UL 489

SQDM9F43245 M9F43245 785901713814
144.66 / EA
  • Amperage: 45 A
  • Certifications: CCC, CSA, IEC, UL
  • Depth: 2.83 in, 72 mm
  • Height: 103 mm, 4.06 in
  • Mounting Type: Clip-On
  • Standard: CSA C22.2 No 5, EN/IEC 60947-2, GB 14048.2, UL 489
  • Strip Length: 0.55 in, 14 mm
  • Voltage: 240 V, 415 V, 440 V
  • Width: 1.42 in, 36 mm
This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 45A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. The electrical endurance is up to 10000 cycles. The mechanical endurance is up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 45A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. The electrical endurance is up to 10000 cycles. The mechanical endurance is up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Offer Sustainability
    • EU RoHs Directive : Compliant
    • Green Premium Status : Green Premium product
    • Mercury Free : Yes
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • Main
    • Trip Unit Technology : Thermal-magnetic
    • Network Type : AC
    • Device Application : Distribution
    • Poles Description : 2P
    • Product Certifications : IEC || CCC || CSA || UL
    • Breaking Capacity : 6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA Icu 240 V AC GB 14048.2 || 10 kA AIR 240 V AC UL 489 || 10 kA AIR 240 V AC CSA C22.2 No 5
    • Product Name : Multi 9 C60
    • Product Or Component Type : Miniature circuit-breaker
    • Number Of Protected Poles : 2
    • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 489 || CSA C22.2 No 5
    • Curve Code : D
    • Device Short Name : C60BP
    • Range : Multi 9
    • In Rated Current : 45 A 77 °F (25 °C) EN/IEC 60947-2
    • Suitability For ISOlation : Yes EN/IEC 60947-2
  • Complementary
    • Connections - Terminals : Tunnel type terminal top or bottom) 0.00…0.05 in² (1…35 mm²) AWG 18...AWG 2) - rigid || Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 3) - flexible with ferrule || Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 3) - flexible
    • Ue Rated Operational Voltage : 240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz
    • Uimp Rated Imp Wstd Voltage : 6 kVEN/IEC 60947-2
    • Ics Rated Service Breaking Cap : 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
    • Colour : Gray
    • Wire Stripping Length : 0.55 in (14 mm) top or bottom
    • Electrical Durability : 10000 cycles
    • Mechanical Durability : 20000 cycles
    • Mounting Mode : Clip-on
    • Contact Position Indicator : Yes
    • Tightening Torque : 30.98 lbf.in (3.5 N.m) top or bottom
    • Mounting Support : DIN rail
    • Local Signalling : ON/OFF indication
    • Control Type : Toggle
    • 9 mm Pitches : 4
    • Width : 1.42 in (36 mm)
    • Earth-Leakage Protection : Without
    • Depth : 2.83 in (72 mm)
    • Height : 4.06 in (103 mm)
    • Ui Rated Insulation Voltage : 500 V AC EN/IEC 60947-2
    • Magnetic Tripping Limit : 12 x In +/- 20 % AC
    • Provision For Padlocking : Padlockable
  • Ordering And Shipping Details
    • Returnability : No
    • Discount Schedule : DE2
    • Country Of Origin : FR
    • Category : 00949 - M9 GEN 2 CB UL489
    • GTIN : 00785901713814
  • Environment
    • Tropicalisation : 2 IEC 60068-1
    • Pollution Degree : 3 EN/IEC 60947-2
    • IP Degree Of Protection : IP20IEC 60529 || IP40 modular enclosure)IEC 60529
    • Ambient Air Temp For Op : -22…158 °F (-30…70 °C)
    • Relative Humidity : 95 % 131 °F (55 °C)
    • Ambient Air Temp For Storage : -40…176 °F (-40…80 °C)
    • Operating Altitude : 0...6561.68 ft (0...2000 m)