KLLU650 - KLLU Series

KLLU650 - KLLU Series

LFUKLLU650 KLLU650 079458271003
0.00 / Each
  • Amperage: 650 A
  • Voltage: 300 V, 600 V
KLLU series UL Listed, time-delay, Class L are quality fuses in every sense of the word. They were developed to provide a somewhat lower priced alternate to the POWR-PRO™ KLPC series fuses. KLLU series fuses meet or exceed all UL requirements for Class L fuses. For superior protection and performance, specification-grade POWR-PRO™ KLPC series fuses are the recommended fuses. Applications:
  • Product Description
  • Features
  • Specifications
KLLU series UL Listed, time-delay, Class L are quality fuses in every sense of the word. They were developed to provide a somewhat lower priced alternate to the POWR-PRO™ KLPC series fuses. KLLU series fuses meet or exceed all UL requirements for Class L fuses. For superior protection and performance, specification-grade POWR-PRO™ KLPC series fuses are the recommended fuses. Applications:
  • Easy to Use
    • 200,000 A.I.R. rating minimizes need for short circuit calculations…meets present and future system requirements.
    • KLLU fuse time-current characteristics closely match typical time-current curves of circuit breakers. Although fuse/circuit breaker systems can seldom be 100% coordinated , KLLU series fuses permit use of a wider range of breaker setting than fast-acting Class L fuses. Excellent protection for a single breaker or a group of breakers.
  • Longer Equipment Life
    • Current limiting — Reduces short circuit damage to systems and equipment.
    • Ten second minimum time delay at 500 percent of rating eliminates needless downtime caused by heavy starting currents of large motors and other inductive loads.
    • 200,000 A.I.R. rating minimizes need for short circuit calculations…meets present and future system requirements.
    • KLLU fuse time-current characteristics closely match typical time-current curves of circuit breakers. Although fuse/circuit breaker systems can seldom be 100% coordinated , KLLU series fuses permit use of a wider range of breaker setting than fast-acting Class L fuses. Excellent protection for a single breaker or a group of breakers.
    • Selective coordination — KLLU fuses coordinate well with other Class L fuses and with all current-limiting Littelfuse fuses rated 600 amps or less. This means less time spent trying to locate short circuits or overloaded equipment, because only the fuse immediately on the line side of the affected circuit opens.
    • Reduced downtime
  • Applications
    • Current limiting — Reduces short circuit damage to systems and equipment.
    • Motor control center mains
    • 200,000 A.I.R. — Provides reliable interruption of all overcurrents up to 200,000 amperes.
    • Service switches
    • Selective coordination — KLLU fuses coordinate well with other Class L fuses and with all current-limiting Littelfuse fuses rated 600 amps or less. This means less time spent trying to locate short circuits or overloaded equipment, because only the fuse immediately on the line side of the affected circuit opens.
    • Ten second minimum time delay at 500 percent of rating eliminates needless downtime caused by heavy starting currents of large motors and other inductive loads.
    • Bolted pressure contact switches
    • UL Listed series-rated protection for molded case circuit breaker panelboards and loadcenters. See panelboard manufacturer’s literature for recommended fuse rating.
    • Large motor branch circuits
    • KLLU fuse time-current characteristics closely match typical time-current curves of circuit breakers. Although fuse/circuit breaker systems can seldom be 100% coordinated , KLLU series fuses permit use of a wider range of breaker setting than fast-acting Class L fuses. Excellent protection for a single breaker or a group of breakers.
    • Reduced downtime
    • Switchboard mains and feeders
    • 200,000 A.I.R. rating minimizes need for short circuit calculations…meets present and future system requirements.
    • When used for motor branch circuit protection, KLLU fuses may be sized close to the motor full-load current, providing excellent protection to branch circuit conductors, motor control equipment and motors.
  • Safety
    • When used for motor branch circuit protection, KLLU fuses may be sized close to the motor full-load current, providing excellent protection to branch circuit conductors, motor control equipment and motors.
    • Current limiting — Reduces short circuit damage to systems and equipment.
    • Selective coordination — KLLU fuses coordinate well with other Class L fuses and with all current-limiting Littelfuse fuses rated 600 amps or less. This means less time spent trying to locate short circuits or overloaded equipment, because only the fuse immediately on the line side of the affected circuit opens.
    • 200,000 A.I.R. — Provides reliable interruption of all overcurrents up to 200,000 amperes.
    • Ten second minimum time delay at 500 percent of rating eliminates needless downtime caused by heavy starting currents of large motors and other inductive loads.
    • 200,000 A.I.R. rating minimizes need for short circuit calculations…meets present and future system requirements.
    • KLLU fuse time-current characteristics closely match typical time-current curves of circuit breakers. Although fuse/circuit breaker systems can seldom be 100% coordinated , KLLU series fuses permit use of a wider range of breaker setting than fast-acting Class L fuses. Excellent protection for a single breaker or a group of breakers.
    • Reduced downtime
  • VAC (V) : 600
  • Interrupting Rating : 200000A@600VAC
  • Ampere Rating (A) : 650
  • VDC (V) : 300
  • Opening : Slo-Blo/Time Lag (T)/Time Delay
  • Package Size : Bolt-In