Nimbus Insulated Aluminum Multi-Tap Connector, Conductor Range 600-4, 4 Ports, Dual Sided Entry, Tin Plated, UL, CSA

Nimbus Insulated Aluminum Multi-Tap Connector, Conductor Range 600-4, 4 Ports, Dual Sided Entry, Tin Plated, UL, CSA

ILSPBTD4500 PBTD-4-500 783669078442
121.12 / Each
Nimbus Insulated Multi-Tap Connector, Dual Sided Entry, Mechanical connection, Dual Rated, Aluminum material, Tin plated connector, UL 486A/B Listed, C22.2 No. 65-03, Copper/Aluminum Primary Conductor 600 kcmil - 4 Str, Contains DE-OX®, 4 conductors, 4 ports/wireways, Plastisol insulation, Drive Type Main 3/8 Internal Hex, rated for 600 V, primary color Black, 1 poles,
  • Product Description
  • Specifications
Nimbus Insulated Multi-Tap Connector, Dual Sided Entry, Mechanical connection, Dual Rated, Aluminum material, Tin plated connector, UL 486A/B Listed, C22.2 No. 65-03, Copper/Aluminum Primary Conductor 600 kcmil - 4 Str, Contains DE-OX®, 4 conductors, 4 ports/wireways, Plastisol insulation, Drive Type Main 3/8 Internal Hex, rated for 600 V, primary color Black, 1 poles,
  • Material : Aluminum
  • UNSPSC Code : 39121408
  • Width (IN) : 3.031
  • Wire Binding Hardware Material : Aluminum
  • UL / CULUS Specification : UL 486A/B Listed
  • Replacement Parts : PORTPLUG-500, SCREWCAP-500
  • CSA File Number : LR-29601
  • Number of Conductors : 4
  • Connection : Mechanical
  • Conductor Size AL (Primary, run, main, line) : 600 kcmil,550 kcmil,500 kcmil,450 kcmil,400 kcmil,350 kcmil,300 kcmil,250 kcmil,4/0 Str,3/0 Str,2/0 Str,1/0 Str,1 Str,2 Str,3 Str,4 Str
  • Height (IN) : 3.034
  • Connector Finish : Tin
  • Upsell : PBTD-4-500-F
  • Number of Usable Ports : 4
  • Flammability Rating : Insulation rated per UL 94
  • Color : Black
  • Environmental Conditions : Cold temperature rated to -45⁰C
  • UPC Code : 78366907844
  • Conductor Size CU (Primary, run, main, line) : 600 kcmil,550 kcmil,500 kcmil,450 kcmil,400 kcmil,350 kcmil,300 kcmil,250 kcmil,4/0 Str,3/0 Str,2/0 Str,1/0 Str,1 Str,2 Str,3 Str,4 Str
  • Weight (LB) : 1.533
  • Conductor Range CU Stranded (Primary, run, main, line) : 600 kcmil - 4 Str
  • Conductor Material : Copper,Aluminum
  • Dual Rated : TRUE
  • Width (mm) : 76.9874
  • CSA Standard : C22.2 No. 65-03
  • Max Insulation OD (mm) : 28.321
  • Number of Poles : 1
  • Conductor Range AL Stranded (Primary, run, main, line) : 600 kcmil - 4 Str
  • Number of Usable Taps : 4
  • UL Control Number : 453G
  • Height (mm) : 77.0636
  • Cap Color Main : Black
  • Voltage Rating : 600 V
  • Number of Ports Main : 4
  • Temperature Rating : 90°C
  • Insulation : Plastisol
  • Max Insulation OD (IN) : 1.115
  • Wire Binding Screw Size : 13/16
  • Number of Ports / Wireways : 4
  • Drive Type Main : Internal Hex
  • Wire Binding Torque : 375
  • Wire Binding Hardware Finish : Tin
  • Length (IN) : 5.343
  • UL File Number : E6207
  • Conductor Type : Stranded
  • Number of Wire Binding Screws per Port : 1
  • Cap Color Tap : Black
  • Wire Binding Screw Size (mm) : 33426.4
  • Drive Size Main : 8-Mar
  • Bag Quantity : 1
  • Contains DE-OX : TRUE
  • Prop65 Compliance : WARNING: Cancer and Reproductive Harm - www.P65warnings.ca.gov