3M™ Cold Shrink QT-III Termination Kit 7621-S-2, Tape, Wire, UniShield®,5-8.7 kV, Insulation OD 0.44-0.89 in, 2 Skirt, 3/kit

3M™ Cold Shrink QT-III Termination Kit 7621-S-2, Tape, Wire, UniShield®,5-8.7 kV, Insulation OD 0.44-0.89 in, 2 Skirt, 3/kit

MMM7621S2 7621-S-2 054007421696
443.28 / Kit
  • Country of Origin: USA
  • Indoor/Outdoor: Outdoor Skirted
  • Insulation Diameter Range: 11.176 mm, 11.43 mm, 11.684 mm, 11.938 mm, 12.192 mm, 12.446 mm, 12.7 mm, 12.954 mm, 13.208 mm, 13.462 mm, 13.716 mm, 13.97 mm, 14.224 mm, 14.478 mm, 14.732 mm, 14.986 mm, 15.24 mm, 15.494 mm, 15.748 mm, 16.002 mm, 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm
  • Number of Conductors: 1
  • Shielding Type: Tape Shield, UniShield®, Wire Shield
  • Voltage: 5 kV, 8 kV, 8.7 kV
  • Voltage Application: Medium Voltage
3M™ Cold Shrink QT III 7620 S, 7680 S & 7690 S Series Termination Kit includes three 1 piece, 3 phase, skirted terminations. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 35kV.
  • Features
  • Product Description
  • Specifications
  • Suitable for outdoor applications
  • High dielectric-constant material regulates the distribution of electric field stress
  • Silicone rubber insulation offers durability and reduces leakage currents in damp conditions
  • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
3M™ Cold Shrink QT III 7620 S, 7680 S & 7690 S Series Termination Kit includes three 1 piece, 3 phase, skirted terminations. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 35kV.
  • Number of Skirts : 2
  • Number of Conductors : 1
  • Breakout Boot : No
  • Cable Insulation Outside Diameter Range (Metric) : 0.44-0.89 in
  • Lug/Stem Connector Included in Kit : No
  • Manufacturer Catalog Number : 7000133210
  • Voltage Application : Medium Voltage
  • Insulation Level : 100%|| 133%
  • Indoor/Outdoor : Outdoor Skirted
  • Insulation Rejacketing : No
  • Insulation Outer Diameter (Metric) : 11.176 mm|| 11.43 mm|| 12.446 mm|| 12.7 mm|| 12.954 mm|| 13.208 mm|| 13.462 mm|| 13.716 mm|| 14.478 mm|| 14.732 mm|| 14.986 mm|| 13.97 mm|| 14.224 mm|| 15.24 mm|| 15.494 mm|| 15.748 mm|| 16.002 mm|| 16.256 mm|| 16.51 mm|| 11.684 mm|| 11.938 mm|| 12.192 mm|| 16.764 mm|| 17.018 mm|| 17.272 mm|| 18.288 mm|| 18.542 mm|| 18.796 mm|| 19.05 mm|| 19.304 mm|| 19.558 mm|| 20.32 mm|| 20.574 mm|| 20.828 mm|| 19.812 mm|| 20.066 mm|| 21.082 mm|| 21.336 mm|| 21.59 mm|| 21.844 mm|| 22.098 mm|| 22.352 mm|| 17.526 mm|| 17.78 mm|| 18.034 mm|| 22.606 mm
  • Manufacturing Origin : USA
  • Maximum Installed Length : 10.50 in
  • Conductor Size by Voltage : (5 kV) 2-3/0 AWG, (8 kV) 4-2/0 AWG
  • Insulation Outer Diameter (Imperial) : 0.44 in|| 0.45 in|| 0.49 in|| 0.5 in|| 0.51 in|| 0.52 in|| 0.53 in|| 0.54 in|| 0.57 in|| 0.58 in|| 0.59 in|| 0.55 in|| 0.56 in|| 0.6 in|| 0.61 in|| 0.62 in|| 0.63 in|| 0.64 in|| 0.65 in|| 0.46 in|| 0.47 in|| 0.48 in|| 0.66 in|| 0.67 in|| 0.68 in|| 0.72 in|| 0.73 in|| 0.74 in|| 0.75 in|| 0.76 in|| 0.77 in|| 0.8 in|| 0.81 in|| 0.82 in|| 0.78 in|| 0.79 in|| 0.83 in|| 0.84 in|| 0.85 in|| 0.86 in|| 0.87 in|| 0.88 in|| 0.69 in|| 0.7 in|| 0.71 in|| 0.89 in
  • Voltage : 5 kV|| 8 kV|| 8.7 kV
  • Cable Shielding : Tape Shield|| UniShield®|| Wire Shield