3M™ Cold Shrink QT-III Termination Kit 7621-S-2, Tape, Wire, UniShield®,5-8.7 kV, Insulation OD 0.44-0.89 in, 2 Skirt, 3/kit

3M™ Cold Shrink QT-III Termination Kit 7621-S-2, Tape, Wire, UniShield®,5-8.7 kV, Insulation OD 0.44-0.89 in, 2 Skirt, 3/kit

MMM7621S2 7621-S-2 054007421696
473.06 / Kit
  • Country of Origin: USA
  • Indoor/Outdoor: Outdoor Skirted
  • Insulation Diameter Range: 11.176 mm, 11.43 mm, 11.684 mm, 11.938 mm, 12.192 mm, 12.446 mm, 12.7 mm, 12.954 mm, 13.208 mm, 13.462 mm, 13.716 mm, 13.97 mm, 14.224 mm, 14.478 mm, 14.732 mm, 14.986 mm, 15.24 mm, 15.494 mm, 15.748 mm, 16.002 mm, 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm
  • Number of Conductors: 1
  • Shielding Type: Tape Shield, UniShield®, Wire Shield
  • Voltage: 5 kV, 8 kV, 8.7 kV
  • Voltage Application: Medium Voltage
3M™ Cold Shrink QT III 7620 S, 7680 S & 7690 S Series Termination Kit includes three 1 piece, 3 phase, skirted terminations. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 35kV.
  • Features
  • Product Description
  • Specifications
  • Silicone rubber insulation offers durability and reduces leakage currents in damp conditions
  • Suitable for outdoor applications
  • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
  • High dielectric-constant material regulates the distribution of electric field stress
3M™ Cold Shrink QT III 7620 S, 7680 S & 7690 S Series Termination Kit includes three 1 piece, 3 phase, skirted terminations. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 35kV.
  • Number of Skirts : 2
  • Breakout Boot : No
  • Number of Conductors : 1
  • Cable Insulation Outside Diameter Range (Metric) : 0.44-0.89 in
  • Indoor/Outdoor : Outdoor Skirted
  • Manufacturing Origin : USA
  • Cable Shielding : Tape Shield|| UniShield®|| Wire Shield
  • Voltage : 5 kV|| 8 kV|| 8.7 kV
  • Lug/Stem Connector Included in Kit : No
  • Manufacturer Catalog Number : 7000133210
  • Voltage Application : Medium Voltage
  • Insulation Level : 100%|| 133%
  • Insulation Outer Diameter (Metric) : 11.176 mm|| 11.43 mm|| 12.446 mm|| 12.7 mm|| 12.954 mm|| 13.208 mm|| 13.462 mm|| 13.716 mm|| 14.478 mm|| 14.732 mm|| 14.986 mm|| 13.97 mm|| 14.224 mm|| 15.24 mm|| 15.494 mm|| 15.748 mm|| 16.002 mm|| 16.256 mm|| 16.51 mm|| 11.684 mm|| 11.938 mm|| 12.192 mm|| 16.764 mm|| 17.018 mm|| 17.272 mm|| 18.288 mm|| 18.542 mm|| 18.796 mm|| 19.05 mm|| 19.304 mm|| 19.558 mm|| 20.32 mm|| 20.574 mm|| 20.828 mm|| 19.812 mm|| 20.066 mm|| 21.082 mm|| 21.336 mm|| 21.59 mm|| 21.844 mm|| 22.098 mm|| 22.352 mm|| 17.526 mm|| 17.78 mm|| 18.034 mm|| 22.606 mm
  • Insulation Rejacketing : No
  • Conductor Size by Voltage : (5 kV) 2-3/0 AWG, (8 kV) 4-2/0 AWG
  • Maximum Installed Length : 10.50 in
  • Insulation Outer Diameter (Imperial) : 0.44 in|| 0.45 in|| 0.49 in|| 0.5 in|| 0.51 in|| 0.52 in|| 0.53 in|| 0.54 in|| 0.57 in|| 0.58 in|| 0.59 in|| 0.55 in|| 0.56 in|| 0.6 in|| 0.61 in|| 0.62 in|| 0.63 in|| 0.64 in|| 0.65 in|| 0.46 in|| 0.47 in|| 0.48 in|| 0.66 in|| 0.67 in|| 0.68 in|| 0.72 in|| 0.73 in|| 0.74 in|| 0.75 in|| 0.76 in|| 0.77 in|| 0.8 in|| 0.81 in|| 0.82 in|| 0.78 in|| 0.79 in|| 0.83 in|| 0.84 in|| 0.85 in|| 0.86 in|| 0.87 in|| 0.88 in|| 0.69 in|| 0.7 in|| 0.71 in|| 0.89 in