TOPJOB®S fuse disconnect terminal block; with pivoting fuse holder for 5 x 20 mm fuse; with blown fuse LED indication for 12 - 30 V; rail mount; 2-conductor; 6.2 mm wide; gray

2 COND TJS PVT FUSE TERM GREY

WGO200216111000541 2002-1611/1000-541 4045454789985
13.44 / EA
http://schema.org/OutOfStock
  • Actuator: Operating Tool
  • Conductor Material: Copper
  • Conductor Size: 12 AWG, 4 mm
  • Country of Origin: China
  • Current: 10 A, 6.3 A
  • Flammability Class: V0
  • Height: 2.602 in, 66.1 mm
  • Insulation Material: Polyamide
  • Mounting Type: DIN-35 Rail
  • Operating Temperature: 70 °C
  • Package Type: Box
  • Strip Length: 0.47 in, 12 mm
  • Voltage: 250 V, 30 V
  • Weight: 13.440 g
  • Width: 0.244 in, 6.2 mm
QTY
  • Features
  • Specifications
  • Approvals
    • DEKRA Certification B.V., CCA, NTR NL 7892, EN 60947
    • KIWA Netherlands B.V., IECEx, IECEx KIWA 17.0014U Ex ec IIC Gc, EN 60079
    • KIWA Netherlands B.V., ATEX, KIWA 17ATEX0030 U, EN 60079
    • CNEX, CCC, 2020312313000180, GB/T 3836.3
    • American Bureau of Shipping, ABS, 20-HG1941090-PDA, EN 60947
    • DEKRA Certification B.V., CCA, 71-120369, EN 60947
    • Underwriters Laboratories Inc., AEx, E185892, UL 60079
    • Underwriters Laboratories Inc., UL, E45172, UL 1059
    • WAGO GmbH & Co. KG, Railway, Railway Ready
    • Det Norske Veritas, Germanischer Lloyd, DNV GL, TAE00001V2
  • Ratings Per Iec/En
    • Ratings per : IEC/EN 60947-7-3
    • Ratings (note) : Electrical ratings are given by the fuse and blown fuse indication.
    • Nominal voltage (III/3) : 250 V
    • Rated impulse voltage (III/3) : 6 kV
    • Rated current : 6.3 A
    • Note (rated current) : Leakage current in case of a blown fuse: LED 2.2 mA (at 24 V operating voltage)
    • Operation status indicator : 12 … 30 V
    • Legend (ratings) : (III / 3) ≙ Overvoltage category III / Pollution degree 3
  • Ratings Per Iec/En 2
    • Ratings per 2 : IEC/EN 60947-7-3
    • Rated voltage (III/3) 2 : 30 V
    • Rated surge voltage (III/3) 2 : 0.8 kV
  • Environmental Requirements
    • Ambient temperature (operation) : -35 … +70 °C
    • Processing temperature : -35 … +70 °C
    • Continuous operating temperature : -35 … +70 °C
  • Physical Data
    • Width : 6.2 mm / 0.244 inches
    • Height : 66.1 mm / 2.602 inches
    • Depth from upper-edge of DIN-rail : 57.2 mm / 2.252 inches
  • Material Data
  • Mechanical Data
    • Mounting type : DIN-35 rail
    • Marking level : Center/side marking
  • General
    • Fuse receptacle : Pivoting
    • Fuse type : Cylindrical fuse; 5 x 20 mm
  • Specifications
    • Product Group Code : 0022
  • Commercial Data
    • Packaging type : Box
    • Country of origin : CN
    • GTIN : 4045454789985
    • Customs tariff number : 85369095000
  • Ex Information
    • Reference hazardous areas : See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
    • Ratings per : ATEX: KIWA 17 ATEX 0030 U / IECEx: KIWA 17.0014U (Ex ec IIC Gc)
    • Rated voltage EN (Ex e II) : 24 V
    • Rated current (Ex e II) : 6.3 A
  • Ratings Per Csa
    • Approvals per : CSA 22.2 No 158
    • Rated voltage CSA (Use Group B) : 250 V
    • Rated current CSA (Use Group B) : 6.3 A
    • Rated voltage CSA (Use Group C) : 250 V
    • Rated current CSA (Use Group C) : 6.3 A
  • Power Loss
    • Power loss (max.) Pl (max.) (note) : When selecting glass cartridge fuses, make sure that the maximum power loss listed below is not exceeded. The power loss is determined according to IEC or EN 60947-7-3/VDE 0611-6 at 23°C. The temperature rise of the terminal block must be checked according to their application and mounting. Higher ambient temperatures represent an additional impact on miniature fuses. Therefore, in such applications, the rated current must be reduced if necessary. More details are available from the manufacturers.
    • Power loss Pl max. overload and short-circuit protection (individual arrangement) : 1.6 W
    • Power loss Pl max. overload and short-circuit protection (group arrangement) : 1.6 W
    • Power loss Pl max. short-circuit protection (individual arrangement) : 2.5 W
    • Power loss Pl max. short-circuit protection (group arrangement) : 2.5 W
  • Connection 1
    • Connection technology : Push-in CAGE CLAMP®
    • Actuation type : Operating tool
    • Connectable conductor materials : Copper
    • Nominal cross-section : 2.5 mm²
    • Solid conductor : 0.25 … 4 mm² / 22 … 12 AWG
    • Solid conductor; push-in termination : 0.75 … 4 mm² / 18 … 12 AWG
    • Fine-stranded conductor : 0.25 … 4 mm² / 22 … 12 AWG
    • Fine-stranded conductor; with insulated ferrule : 0.25 … 2.5 mm² / 22 … 14 AWG
    • Fine-stranded conductor; with ferrule; push-in termination : 1 … 2.5 mm² / 18 … 14 AWG
    • Note (conductor cross-section) : Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
    • Strip length : 10 … 12 mm / 0.39 … 0.47 inches
    • Wiring direction : Front-entry wiring
  • Ratings Per Ul 1059
    • Approvals per : UL 1059
    • Rated voltage UL (Use Group B) : 30 V
    • Rated current UL (Use Group B) : 10 A
    • Rated voltage UL (Use Group C) : 30 V
    • Rated current UL (Use Group C) : 10 A
    • Rated voltage UL (Use Group D) : 30 V
    • Rated current UL (Use Group D) : 10 A