Safety switch, Telemecanique Safety switches XCS, metal XCSE, 1NC+2 NO, slow break, 2 entries tapped Pg 13, 24 V

SAFETY INTERLOCK 300VAC 5A T-X

SQDXCSE5311 XCSE5311 T3389110719536
691.37 / EA
http://schema.org/OutOfStock
  • Certifications: CSA, UL
  • Chain/Cable Diameter: 9-12 mm
  • Depth: 44 mm
  • Height: 146-146 mm
  • Net Weight: 1.14 kg
  • Number of Poles: 3
  • Standard: CSA C22.2 No 14, EN 1088/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/ISO 12100, UL 508
  • Storage Temperature: -40-70 °C
  • Warranty Length: 18 mth
  • Width: 98 mm
This XCSE Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a robust red coated rectangular Zamak body with 2 x Pg 13.5 cable gland entries, allowing for flexible installation. It has 2 normally open and 1 normally closed break-before-make (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 1 normally open and 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
QTY
  • Product Description
  • Specifications
This XCSE Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a robust red coated rectangular Zamak body with 2 x Pg 13.5 cable gland entries, allowing for flexible installation. It has 2 normally open and 1 normally closed break-before-make (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 1 normally open and 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
  • Specifications
    • [Us] Rated Supply Voltage : 24 V - 20...10 %
    • Range Of Product : Telemecanique Safety switches XCS
    • Cable Entry : 2 entries tapped Pg 13.5
    • Electrical Connection : terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
    • Locking Options Description : with interlocking, locking by solenoid
    • Solenoid Contacts Type And Composition : 1 NC + 1 NO slow-break, simultaneous)
    • Product Or Component Type : safety switch
    • Signalling Circuit Voltage : 24/48 V 20...52 V)
    • Component Name : XCSE
    • Design : rectangular
    • Material : metal
    • Head Type : key operated turret head
    • Contacts Type And Composition : 1 NC + 2 NO
    • Contact Operation : slow-break, break before make
    • Local Signalling : for guard open/guard closed and locked 2 LEDs (green or orange)
    • Electromagnet Interlocking : locking on de-energisation and unlocking on energisation of solenoid
    • Cable Outer Diameter : 9-12 mm
    • Number Of Poles : 3
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Height : 146-146 mm
    • Short-Circuit Protection : 10 A cartridge fuse gG (gl)
    • Minimum Actuation Speed : 0.01 m/s
    • Signalling Circuit Consumption : 7 mA
    • [Ithe] Conventional Enclosed Thermal Current : 6 A
    • Power Consumption In Va : 10 VA inrush || 10 VA sealed
    • Supply Voltage Type : AC/DC
    • Head Material : zamak
    • Signalling Circuit Type : AC/DC
    • Net Weight : 1.14 kg
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV EN/IEC 60947-5-1
    • Maximum Operating Rate : 10 cyc/mn for maximum durability
    • [Ui] Rated Insulation Voltage : 50 VEN/IEC 60947-1 signalling circuit
    • Positive Opening : with NC contact
    • Load Factor : 1
    • [Ie] Rated Operational Current : 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
    • Minimum Actuator Force For Extraction : 20 N
    • Mechanical Durability : 1000000 cycles
    • Maximum Actuation Speed : 0.5 m/s
    • Body Material : zamak
    • Safety Reliability Data : B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
    • Width : 98 mm
    • Actuator Forcible Withdrawal Rtc : 2000 N
    • Depth : 44 mm
    • Protection Type : overvoltage protection signalling circuit
    • Supply Frequency : 50/60 Hz
    • Safety Level : can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110916EN
    • Sustainable Offer Status : Green Premium product
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI110903EN
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Environment
    • Product Certifications : UL || CSA
    • Ambient Air Temperature For Operation : -25-40 °C
    • Standards : EN/IEC 60204-1 || EN 1088/ISO 14119 || EN/ISO 12100 || UL 508 || EN/IEC 60947-5-1 || CSA C22.2 No 14
    • Shock Resistance : 10 gn 11 ms IEC 60068-2-27
    • Vibration Resistance : 5 gn 10-500 Hz)IEC 60068-2-6
    • Ip Degree Of Protection : IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
    • Ambient Air Temperature For Storage : -40-70 °C
    • Electrical Shock Protection Class : class I EN/IEC 61140
    • Protective Treatment : TC