multifunction relay, Harmony Timer Relays, 8A, 1 CO, 0.05s…300h, on delay, 24...240V AC DC

TIMER, 24-240VAC/VDC IN, 8A S

SQDRE22R1MAMR RE22R1MAMR 3606480792427
79.11 / EA
http://schema.org/OutOfStock
  • Certifications: CCC, CE, CSA, EAC, GL, RCM, UL
  • Input Voltage: 2.4 V
  • Net Weight: 0.1 kg
  • Standard: IEC 61812-1, UL 508
  • Storage Temperature: -40-70 °C
  • Width: 22.5 mm
This Harmony RE22 timing relay can be set between 0.5mm wide and can be supplied with 24V to 240V AC. This modular timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It also offers a sealable cover, simple and precise settings with rotary trimmers. Status display with 2 LEDs, visually inspect the status of you system without specialized tools. Diagnostic button allows simple setup and trouble shooting by non-specialists. 0 0 0 0 0 0 0 0 0 0 0 0 0 0
QTY
  • Product Description
  • Specifications
This Harmony RE22 timing relay can be set between 0.5mm wide and can be supplied with 24V to 240V AC. This modular timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It also offers a sealable cover, simple and precise settings with rotary trimmers. Status display with 2 LEDs, visually inspect the status of you system without specialized tools. Diagnostic button allows simple setup and trouble shooting by non-specialists. 0 0 0 0 0 0 0 0 0 0 0 0 0 0
  • Complementary
    • Power Consumption In W : 1.5 W 240 V DC
    • Safety Reliability Data : B10d = 190000 || MTTFd = 205.4 years
    • Contacts Type And Composition : 1 C/O timed contact, cadmium free
    • Setting Accuracy Of Time Delay : +/- 10 % of full scale 25 °C IEC 61812-1
    • Creepage Distance : 4 kV/3 IEC 60664-1
    • Maximum Delay Response : 100 ms
    • Control Type : rotary knob || diagnostic button || potentiometer external
    • Insulation Resistance : 100 MOhm 500 V DC IEC 60664-1
    • Immunity To Microbreaks : 10 ms
    • Power Consumption In Va : 3-3 VA 240 V AC
    • Switching Capacity In Va : 2000 VA
    • Minimum Pulse Duration : 100 ms with load in parallel || 30 ms
    • Maximum Switching Current : 8 A
    • Voltage Range : 0.85...1.1 Us
    • Net Weight : 0.1 kg
    • Mounting Position : any position
    • Voltage Drift : +/- 0.2 %/V
    • Reset Time : 120 ms on de-energisation
    • Maximum Switching Voltage : 250 V AC
    • Connections - Terminals : screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
    • [Us] Rated Supply Voltage : 24...240 V AC/DC 50/60 Hz
    • Temperature Drift : +/- 0.05 %/°C
    • Time Delay Range : 3...30 h || 0.05...1 s || 30...300 s || 3...30 min || 3...30 s || 30...300 h || 30...300 min || 0.3...3 s || 10...100 s || 1...10 s
    • Minimum Switching Current : 10 mA 5 V DC
    • Overvoltage Category : III IEC 60664-1
    • Input Voltage : <= 2.4 V
    • Mounting Support : 35 mm DIN rail conforming to IEC 60715
    • Electrical Durability : 100000 cycles, 8 A at 250 V, AC-1 || 100000 cycles, 2 A at 24 V, DC-1
    • Mechanical Durability : 10000000 cycles
    • Housing Material : self-extinguishing
    • Status Led : Green LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED fast flashing)timing in progress and output relay de-energised || Yellow LED slow flashing)timing in progress and output relay energised
    • [Uimp] Rated Impulse Withstand Voltage : 5 kV 1.2-50 µs IEC 60664-1
    • Width : 22.5 mm
    • Time Delay Type : power on-delay
    • Tightening Torque : 0.6-1 N.m IEC 60947-1
    • Supply Frequency : 50...60 Hz +/- 5 %
    • Repeat Accuracy : +/- 0.5 % IEC 61812-1
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1401008EN
    • Sustainable Offer Status : Green Premium product
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • China Rohs Regulation : X
    • Circularity Profile : ENVEOLI1401008EN
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Environment
    • Product Certifications : EAC || CSA || RCM || UL || GL || CE || CCC
    • Ambient Air Temperature For Operation : -20-60 °C
    • Standards : UL 508 || IEC 61812-1
    • Electromagnetic Compatibility : fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 || surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 || surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 || electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 || electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 || conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 || fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 || immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 || immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
    • Dielectric Strength : 2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1
    • Shock Resistance : 15 gn not operating 11 ms IEC 60068-2-27 || 5 gn in operation 11 ms IEC 60068-2-27
    • Vibration Resistance : 20 m/s² 10-150 Hz)IEC 60068-2-6
    • Pollution Degree : 3 IEC 60664-1
    • Directives : 2006/95/EC - low voltage directive || 2004/108/EC - electromagnetic compatibility
    • Ambient Air Temperature For Storage : -40-70 °C
    • Relative Humidity : 95-95 % 25-55 °C
    • Ip Degree Of Protection : IP40 housing: conforming to IEC 60529 || IP50 front face: conforming to IEC 60529 || IP20 terminals: conforming to IEC 60529
  • Specifications
    • Discrete Output Type : relay
    • Range Of Product : Harmony Timer Relays
    • Product Or Component Type : multifunction relay
    • Nominal Output Current : 8 A
    • Device Short Name : RE22