module XPSAC - Emergency stop - 24 V AC DC

RELAY E-STOP

SQDXPSAC5121P XPSAC5121P 3389110274066
235.45 / EA
http://schema.org/OutOfStock
  • Certifications: CSA, TÜV, UL
  • Current: 24 V, 40 mA, 90 mA
  • Net Weight: 0.16 kg
  • Standard: EN 1088/ISO 14119, EN 60204-1, EN/IEC 60947-5-1, EN/ISO 13850
  • Storage Temperature: -25-85 °C
  • Warranty Length: 18 mth
This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. 24V AC/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.
QTY
  • Product Description
  • Specifications
This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. 24V AC/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.
  • Environment
    • Product Certifications : UL || CSA || TÜV
    • Ambient Air Temperature For Operation : -10-55 °C
    • Standards : EN/ISO 13850 || EN/IEC 60947-5-1 || EN 60204-1 || EN 1088/ISO 14119
    • Ip Degree Of Protection : IP20 terminals)EN/IEC 60529 || IP40 enclosure)EN/IEC 60529
    • Ambient Air Temperature For Storage : -25-85 °C
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1406024EN
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : X
    • Circularity Profile : ENVEOLI1406024EN
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Complementary
    • [Uc] Control Circuit Voltage : 24 V
    • Mounting Support : 35 mm symmetrical DIN rail
    • Output Thermal Current : 6 A per relay relay output
    • Minimum Output Voltage : 16 V relay output
    • Current Consumption : 40 mA 24 V DC on power supply || 90 mA 24 V AC on power supply
    • Minimum Output Current : 10 mA relay output
    • [Ith] Conventional Free Air Thermal Current : 10.5 A
    • Associated Fuse Rating : 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 || 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
    • [Uimp] Rated Impulse Withstand Voltage : 4 kV III IEC 60947-5-1 || 4 kV III DIN VDE 0110 part 1
    • Net Weight : 0.16 kg
    • [Ui] Rated Insulation Voltage : 300 V 2)IEC 60947-5-1 || 300 V 2)DIN VDE 0110 part 1
    • Local Signalling : 2 LEDs
    • Breaking Capacity : 1.5 A 24 V DC-13)50 ms relay output
    • Maximum Power Consumption In Va : 2.5 VA AC
    • Maximum Power Consumption In W : 1.2 W DC
    • Supply Frequency : 50/60 Hz
    • Maximum Response Time On Input Open : 100 ms
    • Breaking Capacity : 180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output
  • Specifications
    • [Us] Rated Supply Voltage : 24 V AC - 20...10 % || 24 V DC - 20...20 %
    • Range Of Product : Preventa Safety automation
    • Product Or Component Type : Preventa safety module
    • Safety Module Name : XPSAC
    • Type Of Start : unmonitored
    • Output Type : relay instantaneous opening, 3 NO, volt-free
    • Connections - Terminals : captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel || captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
    • Number Of Additional Circuits : 1 solid state output
    • Safety Module Application : for emergency stop and switch monitoring
    • Safety Reliability Data : MTTFd = 210.4 years EN/ISO 13849-1 || DC > 99 % EN/ISO 13849-1 || PFHd = 3.56E-9 1/h EN/IEC 62061
    • Function Of Module : switch monitoring || emergency stop
    • Safety Level : can reach PL e/category 4 EN/ISO 13849-1 || can reach SILCL 3 EN/IEC 62061