module XPS-PV - hydraulic valves on linear presses - 24 V DC

MODULE XPS-PV - HYDRAULIC VALV

SQDXPSPVT1180 3389110724837
536.69 / EA
http://schema.org/OutOfStock
  • Certifications: CSA, TÜV, UL
  • Depth: 118 mm
  • Enclosure Material: Polycarbonate
  • Height: 73 mm
  • Net Weight: 0.54 kg
  • Standard: IEC 60204-1, IEC 60947-5-1, IEC 693
  • Storage Temperature: -25-85 °C
  • Warranty Length: 18 mth
  • Width: 100 mm
QTY
  • Specifications
  • Environment
    • Product Certifications : CSA || UL || TÜV
    • Ambient Air Temperature For Operation : -10-55 °C
    • Standards : IEC 693 || IEC 60204-1 || IEC 60947-5-1
    • Ip Degree Of Protection : IP20 terminals)IEC 60529 || IP40 enclosure)IEC 60529
    • Ambient Air Temperature For Storage : -25-85 °C
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1408008EN
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : X
    • Circularity Profile : ENVEOLI1408008EN
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Complementary
    • Height : 73 mm
    • Mounting Support : 35 mm symmetrical DIN rail
    • Power Consumption In W : 6 W
    • Minimum Output Voltage : 17 V relay output
    • Minimum Output Current : 10 mA relay output
    • [Ith] Conventional Free Air Thermal Current : 2.5 A
    • Associated Fuse Rating : 4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
    • Minimum Output Wiping Time : 100 ms
    • [Uimp] Rated Impulse Withstand Voltage : 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
    • Net Weight : 0.54 kg
    • Connections - Terminals : captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² with cable end || captive screw clamp terminals, 2 x 2.5 mm² without cable end
    • [Ui] Rated Insulation Voltage : 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
    • Local Signalling : 8 LEDs
    • Number Of Terminal Blocks : 20
    • Enclosure Material : polycarbonate
    • Width : 100 mm
    • Depth : 118 mm
    • Breaking Capacity : 1.5 A 24 V DC-13)50 ms relay output
    • Maximum Response Time On Input Open : 15 ms
    • Breaking Capacity : 180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output
  • Specifications
    • [Us] Rated Supply Voltage : 24 V DC - 10...10 %
    • Range Of Product : Preventa Safety automation
    • Product Or Component Type : Preventa safety module
    • Enclosure Type : removable
    • Safety Module Name : XPSPVT
    • Output Type : relay, 2 NO + 1 NC, volt-free
    • Safety Module Application : for dynamic monitoring of hydraulic valves on linear presses
    • Safety Reliability Data : MTTFd = 50.9 years ISO 13849-1 || DC = 0...99 % ISO 13849-1 || PFHd = 2.24E-8 1/h IEC 62061
    • Function Of Module : monitoring hydraulic valves
    • Safety Level : can reach PL e/category 4 ISO 13849-1 || can reach SILCL 3 IEC 62061