NEMA Contactor, Type S, nonreversing, Size 0, 18A, 5 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, NEMA 12

CONTACTOR 600VAC 18AMP NEMA +O

SQD8502SBA2V02S 8502SBA2V02S 785901177067
626.69 / EACH
http://schema.org/OutOfStock
  • Certifications: CSA, UL Listed File E78351 CCN NLDX
  • Contact Configuration: Without
  • Depth: 217 mm
  • Height: 324 mm
  • Line Rated Current: 18 A
  • Number of Phases: 3
  • Warranty Length: 18 mth
  • Width: 162 mm
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 0 non-reversing contactor has an 18 ampere rating. Three phase NEMA Size 0 contactors have 3 HP at 200 and 230 VAC and 5 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is in a NEMA 3R rainproof NEMA 12 dusttight enclosure. This enclosure is 12.75 inches tall, 6.38 inches wide and 8.52 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
QTY
  • Product Description
  • Specifications
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 0 non-reversing contactor has an 18 ampere rating. Three phase NEMA Size 0 contactors have 3 HP at 200 and 230 VAC and 5 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is in a NEMA 3R rainproof NEMA 12 dusttight enclosure. This enclosure is 12.75 inches tall, 6.38 inches wide and 8.52 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
  • Specifications
    • Range Of Product : 8502S
    • Contactor Application : non-reversing
    • Product Or Component Type : contactor
  • Contractual warranty
    • Warranty : 18 months
  • Environmental
    • Product Certifications : UL listed file E78351 CCN NLDX || CSA
    • Nema Degree Of Protection : NEMA 12 painted sheet steel
  • Complementary
    • Local Signalling : no indicator
    • Height : 324 mm
    • Auxiliary Contact Composition : without
    • Nema Size : 0
    • [Uc] Control Circuit Voltage : 120 V AC 60 Hz || 110 V AC 50 Hz
    • Poles Description : 3P
    • Rated Power In Hp : 3 HP 200 V AC || 3 HP 230 V AC || 5 HP 460 V AC || 5 HP 575 V AC
    • Electrical Connection : screw clamp terminals
    • Provided Equipment : fuse not supplied
    • Product Compatibility : circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC || fuse J 60 A maximum, SCCR: 100 kA at 600 V AC || fuse T 60 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC
    • Line Rated Current : 18 A
    • Control Type : no control units
    • Control Circuit : separate control circuit
    • Width : 162 mm
    • Depth : 217 mm
    • Phase : 3 phase
    • [Ue] Rated Operational Voltage : 600 V AC
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Eu Rohs Directive : Not compliant
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov